Dual Loop Control Variable Frequency Drive Controller Speed Control For Steel Plant

Brand Name : Noker

Model Number : JD-BP38-1200F

Certification : ISO9001

Place of Origin : China

MOQ : 1 set

Price : To be discussed later

Payment Terms : L/C, T/T, Western Union

Supply Ability : 1000 set per month

Delivery Time : 15-20 work days

Packaging Details : Wooden Packing

PID : Built-in PID regulator

Close Loop : Dual loop control power supply

Control Mode : Multiple control methods

Quick maintenance : Accurate fault location and recording function

Protection mechanism : Perfect protection mechanism

Frequency setting modes : Multi mode

Contact Now

Dual Loop Control Variable Frequency Drive Controller 3 Phase Speed Control For Steel Plant

Three Phase 10KV 1200KW Medium Voltage Electric Motor Speed Control For Steel Plant And Power Station, with high speed DSP as the control core, uses space voltage vector control technology, power unit series multilevel technology, with high reliability, easy operation and high performance as the design target, meets the user's various load speed control energy saving, improves the production process needs, is a high to high voltage source type frequency converter. Its harmonic finger is less than IEE 519-1992 harmonics national standard, high input power factor, good output waveform quality, no need to use input harmonic filter, power factor compensation device and output filter; no harmonic induced motor additional heat and torque ripple, noise, output dv/dt, common mode electric voltage and other problems, can use common asynchronous (or synchronous) motor.

Features

1. Accurate fault location and recording function

2. Operating voltage, current, frequency record can be querying

3. The frequency setting can be given on the spot, the communication is given, etc.

4. frequency presupposition, acceleration and deceleration function

5. With high power density ahead of the peers

6. Small unit volume, modular design4.Dual loop control power supply

7. The secondary winding of transformer is used as backup control power to ensure the safety of the

system during operation.

8. Multiple control methods

9. Unit bus voltage, temperature display function

10. The choice of local control, remote control box control, DCS control

11. Support MODBUS, PROFIBUS and other communication protocols

12. The whole machine is compact and takes up a small space

13. Perfect protection mechanism

14. The unit contains 7 kinds of protection, and the whole machine is still running after the failure.

15. The whole machine includes the protection of the frequency converter and the protection of the

motor

16. High control performance

17. Built-in PID regulator;

18. It can be adapted to different fields by parameter setting, and the output current harmonics are less

than 2% (rated).

Working principle

Dual Loop Control Variable Frequency Drive Controller Speed Control For Steel Plant

Working principle

Dual Loop Control Variable Frequency Drive Controller Speed Control For Steel Plant

Dual Loop Control Variable Frequency Drive Controller Speed Control For Steel Plant

Dual Loop Control Variable Frequency Drive Controller Speed Control For Steel Plant

Dual Loop Control Variable Frequency Drive Controller Speed Control For Steel Plant

Dual Loop Control Variable Frequency Drive Controller Speed Control For Steel Plant

Specification

Item Unit Data
Input Voltage frequency,voltage Three phase,50Hz ,6kV(10kV)
fluctuation voltage:-10% ~ +10%,frequency:±5%,-10% ~ -35%
Basic feature Precision Analog setting:0.3% of the highest frequency setting value
Efficiency >98%,in rating condition
Power factor >0.95
Control factor The time of acceleration and deceleration 0.1~6000.0S,acceleration and deceleration time can be set separately
The feature of voltage and frequency Set by the V/F curve
PID the parameters of PID can be set by hand
The other functions V/F curve, Compensation for the low frequency,rated
Running Operation modes the machine control, remote control, host computer control
Frequency setting modes setting on touch screen, multistage speed setting, analog signal setting (4-20 mA )
Touch screen display over-current of the motor, over-voltage of the inverter, under-voltage of the inverter, over-current of the cell, over-voltage of the cell, over-heat of the cell, lack phase of cell, communication failure.
Protection function over-current of the motor, over-voltage of the inverter, under-voltage of the inverter, over-current of the cell, over-voltage of the cell, over-heat of the cell, lack phase of cell, communication failure.

Environment

Ambient

Ambient Indoor with good ventilation and free from corrosive gas and conductive dust
Altitude Below 1000m. Need to rise the rated power when the altitude is more than 1000m
Temperature -20~+65°C
Humidity 90%RH without dew condensation
Vibration <0.5G
Cooling Forced Air Cooling


Product Tags:

variable frequency controller

      

frequency inverter drive

      
Quality Dual Loop Control Variable Frequency Drive Controller Speed Control For Steel Plant wholesale

Dual Loop Control Variable Frequency Drive Controller Speed Control For Steel Plant Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Noker Electric Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)